Skip to content
Klang IndustrialMs Teh Seok Hoon, PEA 4006

Warehouse vs factory in Klang and Port Klang: specs, power, fire, approvals and using one as the other

Ms Teh Seok Hoon, PEA 4006. Updated

In Klang and Port Klang a warehouse and a factory often share the same steel hall; the difference is use. A warehouse is built around docks, clear height and floor loading for stored goods, a factory around power, machine loads and process approvals. MBDK allows making and processing only in premises with industrial or factory status, and Act 172 treats a material change of use as development, so check approvals, TNB supply and Bomba's rules before switching.

Key takeaways

  • Same shell, different use: most Klang units are listed as factory/warehouse, but the approved use, the licence and the fit-out decide what you may run inside.
  • Power is the clearest gap: a 249,965 sq ft Westport warehouse on Ms Teh's list has 400 A, while a 76,074 sq ft Meru factory has 6,000 A.
  • Bomba draws its lines differently: a storage building over 7,000 m³ is a designated premises, a single-storey factory from 2,001 m² with automatic sprinklers.
  • Making or processing needs premises with industrial or factory status under MBDK's licence conditions, and Act 172 treats a material change of use as development needing planning permission.
  • In the port belt, the Westport and Northport free zones are commercial zones for trading and repacking; free zone manufacturing near Port Klang means the industrial zone in PKFZ or LMW status.
Factory and warehouse hall
Factory and warehouse hall · Illustrative image
MBDK licence rule
Making and processing only in premises with industrial or factory status
Bomba line for storage
More than 7,000 m³ (1998 order)
Bomba line for a single-storey factory
2,001 m² and above with automatic sprinklers
TNB supply from a new substation
Above 350 kVA to 1,000 kVA at 400 V; 11 kV from 1,000 kVA
MIDA manufacturing licence
Shareholders' funds of RM2.5 million or more, or 75 or more full-time staff

One hall, two uses: what actually separates a warehouse from a factory

Walk through the estates of Meru, Kapar or Pulau Indah and most single-storey steel halls look alike, which is why units on Ms Teh's list are described as factory/warehouse. The building type is shared. What differs is the activity inside it, and what the council, Bomba, TNB and other agencies have approved for that activity.

The law draws the line at processing. The Industrial Coordination Act 1975, as set out in MIDA's manufacturing licence guideline, defines manufacturing as making, altering, blending, ornamenting, finishing or otherwise treating or adapting any article or substance, including the assembly of parts, but not activity normally associated with retail or wholesale trade. Storing, sorting, picking and dispatching goods is warehousing. Once goods are made, altered or assembled on site, the premises are being used as a factory.

Klang's council writes the same line into its licences. MBDK's compliance conditions for industrial licences, which cover factories, warehouses and used goods premises under one set of rules, say that any making or processing may only be carried out in premises with industrial or factory status, and that no industrial activity other than the licensed one may be carried out.

Building specs: docks and clear height versus machines and services

A warehouse is designed around the flow of trucks and pallets. The Ministry of Transport's guidebook to starting a warehousing business, published by the National Logistics Task Force in May 2021, sets out the usual design points:

Large warehouses in the port belt follow that pattern. A 249,965 sq ft warehouse at Westport on her list has 20 loading bays, a 49 ft eave and 59 ft apex and a 5 t/m² floor, yet only 400 A of power.

A factory is designed around its process instead: power for machines, the load of each machine on the slab, cranes, ventilation, waste and water. The same guidebook says a floor must withstand the weight of the equipment and installations designed to be placed on it, so a factory buyer asks for the slab design behind a floor loading figure, not just the figure. Her list shows the spread: 1.5 t/m² in a 57,447 sq ft unit in Bandar Sultan Suleiman and a 39,341 sq ft unit in Sungai Kapar Indah, 3 t/m² in a 19,840 sq ft semi-D in Meru, and 5 t/m² at Westport and in a 117,345 sq ft unit in Pandamaran. FactoryHub's floor loading calculator turns racks or machines into a t/m² figure, and our guide to pallet racking in a Klang warehouse covers rack loads and roof clearance.

  • Raised loading docks of 1 to 1.6 m with dock levellers, and an internal aisle of at least 4 m along the docks kept clear of cargo.
  • An apron at least 5 m deep, and at least 20 m (25 m recommended) for trucks to manoeuvre in front of inclined docks.
  • An operating height that usually does not exceed 7.5 m to the lowest ceiling structure, raised for a storage system with at least 0.5 m clear above it.
  • A floor of at least 15 cm of reinforced concrete, thicker where heavier loads are expected.

Loading bays, docks, dock levellers and single or double storey

What is the difference between a loading bay and a loading dock?

A bay is the space where the truck stands; a dock is a raised platform at truck bed height, 1 m to 1.6 m in the Ministry of Transport guidebook, usually with a leveller. Many Klang listings count bays without saying which are raised docks. A 189,000 sq ft warehouse in Bandar Sultan Suleiman on her list has 20 bays: at a viewing, ask how many are docks and how deep each apron is.

Does a warehouse need a dock leveller?

Where the dock is raised and trucks of different heights call, yes in practice: the Ministry of Transport guidebook pairs raised docks of 1 m to 1.6 m with dock levellers so forklifts can drive into the truck bed. A dock leveller is excluded from DOSH's lifting machinery certificates, so it needs servicing, not a PMA. Ground level doors used with side loaders or tail lifts do without one.

How many loading bays does an e-commerce warehouse need?

More than the planning minimum. PLANMalaysia asks for at least two, or one per 1,858 m² up to nine on lots above an acre, but parcel hubs run on many van and lorry arrivals at fixed cut-off times. Count your peak hour arrivals and departures, then add room for vans to queue inside the lot, since MBDK tows heavy vehicles parked on the road. Bukit Raja's parcel hubs show the pattern.

Single storey or double storey factory: which suits a Klang operation?

Single storey suits heavy goods, forklifts and trailers; double storey suits light assembly with offices or storage above. Two storeys bring internal columns, a floor loading figure for each level, and a fire rule of their own: a two storey factory with each floor a separate compartment needs the Fire Certificate route above 1,000 m² in total. Multi-storey warehouses appear in Bukit Raja and Telok Gong.

Power: lighting and forklifts versus production lines

Power is the clearest practical gap. For a warehouse, the Ministry of Transport guidebook suggests giving the power supplier an initial estimate of 80 watts per square metre for lighting, plugs and ventilation only. Where the activity needs special machinery with a higher supply, it says the owner should work it out with the electricity company through a professional electrical contractor.

On Ms Teh's list, the Westport warehouse has 400 A on 249,965 sq ft, while a 76,074 sq ft detached factory in Meru has 6,000 A: fifteen times the power on less than a third of the floor area. FactoryHub's Meru industrial area page has the estate data for that part of Klang.

TNB's supply rules give a three-phase 415 V supply of up to 72 kVA as 100 A, so 400 A is roughly 290 kVA and 6,000 A roughly 4,300 kVA. Its connection guidelines set what each level of maximum demand needs from the network:

So a tenant who wants to put a production line into a warehouse with a few hundred amps is usually asking for a new supply, not a plug-in. Ask the landlord for the main switchboard rating and whether the lot already has a substation, and size your load first with FactoryHub's factory power calculator.

  • Above 100 kVA to 350 kVA: 400 V by underground cable from a feeder pillar or a new or existing substation, subject to TNB's system study.
  • Above 350 kVA to 1,000 kVA: 400 V by direct underground cable from a new substation.
  • 1,000 kVA to under 5,000 kVA: 11 kV through a TNB switching station, with extra land for a main distribution substation (PPU) possibly needed.

Fire: Bomba measures a store by volume and a factory by floor area

The Fire Services (Designated Premises) Order 1998, made under the Fire Services Act 1988, lists the buildings Bomba treats as designated premises, the ones its fire certificate (Perakuan Bomba) rules apply to. Factories and stores sit on different rows with different tests:

Height makes a store cross its line quickly. A 19,840 sq ft semi-D in Meru on her list has a 40 ft eave, about 12.2 m, and under that height about 575 m² of floor, roughly 6,200 sq ft, already encloses 7,000 m³. The single-storey factory row starts at 2,001 m², about 21,500 sq ft, and needs sprinklers, while factories with office floors fall under the two-storey and three-storey rows instead. The same building can therefore come under different fire rules depending on whether it stores or produces.

That is why a change of use, a new rack layout or different goods should go to a fire engineer and Bomba's Klang zone before work starts. MBDK's one stop centre forms include a separate checklist for Bomba plan submissions, and the racking guide linked above explains how alterations to a premises holding a fire certificate are handled.

  • Factory: a single storey of 2,001 m² and above with an automatic sprinkler system; two storeys, each floor built as a separate compartment, of more than 1,000 m² in total; three storeys and above; and special structures or hazardous processes.
  • Storage and general: more than 7,000 cubic metres, or an underground car park of more than 1,000 m².

Approvals and licences: what changes when you produce instead of store

Planning comes first. The Town and Country Planning Act 1976 (Act 172), in PLANMalaysia's consolidated text, counts the making of any material change in the use of any land or building as development, and section 19 bars development without planning permission. Interior works escape that only if they do not change the use of the building or affect its drainage, sanitary arrangements or soundness. MBDK's Town Planning Department lists planning permission for a change of building use (KM tukarguna bangunan) among the applications it processes, and its Building Department says it decides non-residential alteration and addition plans within seven days.

The industrial licence MBDK issues names the activity, and the council publishes a form to add or remove licensed activities. A warehouse operator who starts production applies to change the licence rather than relying on the old one. The conditions also bite harder on a factory: no dust, vapour, heat, gas, smell, vibration, smoke or soot that becomes a nuisance or pollutes the air, and industrial waste removed only by a contractor approved by MBDK's Environmental Services Department.

Enforcement is routine. In January 2026 Sin Chew reported that MBDK's licensing and enforcement teams checked units on Jalan Air Hitam, including scrap metal processing, machine work, used clothing sorting and warehouses storing general goods. Only one factory held a valid 2026 industrial and advertisement licence, and nine compounds were issued under the council's 2007 licensing by-laws. Our guide on what MBDK checks for a factory or warehouse licence walks through the application.

Two more approvals usually apply only to a factory:

  • MIDA manufacturing licence: under the Industrial Coordination Act 1975, a manufacturer with shareholders' funds of RM2.5 million or more, or 75 or more full-time paid employees, must apply to MIDA; smaller companies may apply for an exemption. A warehouse that only stores and distributes is outside this licence.
  • DOSH certificates: with the Factories and Machinery Act 1967 repealed (DOSH), power-driven lifting machinery such as an overhead crane needs design verification and a certificate of fitness before construction, installation or use, under the OSH (Plant Requiring Certificate of Fitness) Regulations 2024 (DOSH).

The port belt twist: free zones at Westport, Northport and PKFZ

Near the ports, customs status matters as much as the building. MIDA's policy booklet explains that free zones are declared under the Free Zones Act 1990 as either Free Commercial Zones (FCZ) or Free Industrial Zones (FIZ). An FCZ is for commercial activity: trading (except retail), breaking bulk, grading, repacking and relabelling. An FIZ is for export manufacturing: companies there should export their entire production or at least 80% of it, and their raw materials or components should be mainly imported.

In Ms Teh's areas, MIDA lists FCZs at the North, South and West Port of Port Klang, and both an FCZ and an FIZ at Pulau Indah in the Port Klang Free Zone, which describes itself as an integrated free commercial and industrial zone (PKFZ). So a free zone warehouse at Westport or Northport is set up for trading and repacking, while free zone manufacturing means the industrial zone in PKFZ. MBDK even keeps a separate building plan checklist for PKFZ on its one stop centre forms page.

Outside free zones, an exporter can apply for licensed manufacturing warehouse (LMW) status, which MIDA says gives facilities similar to factories in an FIZ. Despite the name, an LMW is a factory, so every factory check in this guide still applies. Ordinary industrial estates in Kapar, Meru or Pulau Indah are not free zones at all.

Using a warehouse as a factory, or a factory as a warehouse: the checks

Factory to warehouse is usually the easier move inside an industrial estate, but it is not automatic: storage changes Bomba's test to volume, racks need floor capacity and clearance, and trucks need docks and turning room. Warehouse to factory is the harder direction, because planning, the licence, power, the floor, fire protection and machine certificates may all change at once. Before you sign, work through this list with the landlord:

Most units on her list in Kapar, Meru, Northport and Westport are recorded as medium industry, but the industry class allowed on a lot comes from its title conditions and the local plan, not from a listing. Ms Teh can help you shortlist factories and warehouses in Klang, Meru, Kapar and Port Klang whose power, floor and approvals already match the activity you plan to run.

  • The land title category and conditions, and the approved use on the planning permission and building plans.
  • Whether MBDK treats your change as a material change of use needing planning permission, and the licence activity you will apply for.
  • The main switchboard rating, any substation on the lot and the lead time for a TNB upgrade.
  • The slab design behind the floor loading figure, checked against your heaviest machine or rack.
  • Sprinklers, the current fire certificate if any, and Bomba's view of the new use.
  • Cranes or other plant that need DOSH certificates, and whether MIDA's licence thresholds apply.

More on warehouse specs

FactoryHub, fellow CID agent Peter Tan's site, has wider guides on two questions above: the logistics and e-commerce warehouse requirements it uses to shortlist units, and single storey vs double storey factories.

Questions buyers and tenants ask

Can I run a factory in a unit listed as factory/warehouse in Klang?

Only if the activity fits the unit's approved use and you hold an industrial licence from MBDK for it. MBDK allows making and processing only in premises with industrial or factory status. Check the planning approval and land title, then confirm power, floor loading and fire protection for your process before signing.

Is Pelabuhan Utara (Northport) a free zone where I can manufacture?

MIDA lists the free zone at Northport, like those at Westport and the South Port, as a Free Commercial Zone, meant for trading (except retail), breaking bulk, grading, repacking and relabelling. For export manufacturing in a free zone near Port Klang, MIDA lists the Free Industrial Zone at Pulau Indah in PKFZ; elsewhere a manufacturer can apply for licensed manufacturing warehouse status.

Does a warehouse need a MIDA manufacturing licence?

Not for storage and distribution alone. The Industrial Coordination Act 1975 licence applies to manufacturing activity by companies with shareholders' funds of RM2.5 million or more or 75 or more full-time paid employees. If you start assembling or processing goods in the warehouse, check whether you cross those thresholds.

How much power does a warehouse need compared with a factory?

The Ministry of Transport guidebook uses an initial estimate of 80 W per square metre for a warehouse's lighting, plugs and ventilation; a factory's need depends on its machines. On Ms Teh's list, a 249,965 sq ft Westport warehouse has 400 A, while a 76,074 sq ft Meru factory has 6,000 A. TNB supplies loads from 1,000 kVA at 11 kV.

Does a warehouse in Klang need a Bomba fire certificate?

It does when it is a designated premises. The Fire Services (Designated Premises) Order 1998 includes storage buildings of more than 7,000 cubic metres, which a single-storey warehouse with a 40 ft eave reaches at under 600 m² of floor. Ask the landlord for the current certificate before you sign.

Do I need planning permission to turn a warehouse into a factory?

Possibly. Act 172 treats a material change in the use of a building as development that needs planning permission, and MBDK's Town Planning Department processes planning permission for a change of building use. Whether a switch from storage to production counts depends on the approval and the local plan, so ask MBDK before work starts.

Can a factory in Klang be converted into a logistics warehouse?

Usually, but check four things. The approved use: ask MBDK whether it is a material change of use needing planning permission, and change the licence activity. Fire: Bomba measures a store by volume, and storage above 7,000 m³ falls under the Fire Certificate rules. The floor and docks must suit racking and trailers. And the title's express conditions must not rule storage out.

Units in these places

Tell Ms Teh what you need

Send the size, power, ceiling height, budget and move-in date you need on WhatsApp, or call her directly.

WhatsApp Ms TehCall